Pancretan Stadium : Inspection of structural adequacy - NDT inspection of metal beams at the roof.

As NDT method we used the method of ultrasonic for the sample ultrasound measurement of the metal cross section at vital parts of the construction. The findings of the inspection were greatly interesting as the damage was so extensive as to prohibit the access of the human resources for safety reasons.